Temporary Works
Construction of access road; 300 mm thick gatch
course laid on 300 mm thick compacted soil;
including road marking, signage, reflective stands,
kerbs, excavation and all necessary fixings and
accessories and making good to match existing
road finishes upon completion of the works;
as shown on Drawing Nr. TP2-ACM-02310-DGEA-1021;
allin accordance with the Specifications
Temporary access road m2
Carefully take up and store on site, clean, make
good and reinstate upon completion of the work
existing landscaping (at location of temporary
access road) at grade, above grade and below
grade; complete as shown on Drawing Nr.
TP2-ACM-02310-DG-EA1025 and in accordance
with the Specifications
Grassed areas
Trees
Footpaths
Cycling track
Relocation of existing irrigation line
comprising theexcavation and careful removal of
existing irrigation pipework an approximate length
of 96 m), stored at site for later re-use, filling and
compacting existing trench, excavation of new
trench and relaying of existing pipework (taken
from store) using new pipework where required (an
approximate length of 116 m) including excavation,
disposal, pipe laying and jointing, bedding and
surround, backfilling pipe trench,making good and
accessories / ancillaries complete as shown on
Drawing Nr. TP2-ACM-02310-DG-EA3002;
and in accordance with the Specifications
Existing irrigation line
Protection of salvage structures and utilities; all
including excavation, disposal, pipe laying and
jointing, bedding and surround, backfilling pipe
trench, marker tape, making good and accessories
/ ancillaries complete as shown on Drawing
Nr. TP2-ACM-02310-DG-EA3002 & EA3004; all in
accordance with the Specifications
Existing lighting cables (approximate length
175 m)
Precast concrete protection of salvage structures
andutilities; all including excavation, disposal, pipe
laying and jointing, bedding and surround,
backfilling pipe trench,
marker tape, making good and accessories /
ancillaries complete as shown on Drawing Nr.
TP2-ACM-02310-DG-EA3005; all in accordance with
the Specifications
Existing 400 mm diameter gas line
Carefully remove, store and handover to relevant
authorities (including transportation) for reinstalling
elsewhere on site at grade, above grade, and
below grade; complete as shown on Drawing Nr.
TP2-ACM-02310-DG-EA1025 and in accordance
with the Specifications
Existing street light pole