VCDC Firmware - Problem solving
$30-250 SGD
Betales ved levering
I am stuck with communition with device. Please find the below information and pls guide on vdip commands sequence
// 1) we used tool called [login to view URL] to modify the FTD file which you given to us and find the below changes in FW.
Firmware Settings
Firmware Version: 03.68-123 (Modified)
Firmware Type: VCDC FTD Upgrader File for Main Code
Default Monitor Settings: 115200 baud, 8 bits, 1 stop bit, no parity, no flow control
Initial Mode: SCS, IPA, LED Flash at Power-on
Options: Allow Firmware Upgrades, Allow Data Mode,
Show Prompt, Show Device Connects/Removals, Show Version Report at Startup.
// 2) Sensor device details
FTDIBUS\COMPORT&VID_19CE&PID_9073
device name: SINUS SLM Tango (907.3)
MANUFATURE SINUS Messtechnik GmbH
Serial Settings of the device:
Baud rate: 115200 Baud
Data bits: 8 Bit
Stop bits: 1 Bit
Parity: None
// 3) power up the VDIP1 module( board setting: DATAREQ# and DATAACK# left open. CTS# & RTS# connected together)
Ver 03.68-123VCDCF On-Line:<CR>
DD2<CR>
// QP1
2B 0D
[RX] - $00 $00 <CR>
// QP2
2C 0D
[RX] - $40 $00 <CR>
//Query Device
85 20 40 00 0D
[RX] - $01 $08 $81 $40 $02 $40 $00 $40 $01 $02 $00 $FF $FF $FF $CE $19 $73 $90 $00 $06 $01 $00 $00 $00 $00 $00 $00 $00 $00 $00 $00 $00 <CR>
><CR>
// Firmware version
13 0D
[RX] - <CR>
MAIN 03.68-123VCDCF<CR>
Command Failed RPRG 1.00R<CR>
><CR>
// set FTDI
87 20 40 0D
><CR>
// QP2
2C 0D
[RX] - $01 $00 <CR>
// Set Current
86 20 01 0D
><CR>
//PULL down (GND) DATAREQ# TO ENABLE DATADODE and DATAACK# left open. CTS# & RTS# remain connected together.
// Output after pull down the DATAREQ#
<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`<SOH>`
Device Removed P2